Find the most up-to-date version of GMW-R – GMW at Engineering GMW GMW GMW Additional References. EIA/JEDEC JESDAB. © Copyright General Motors Corporation All Rights. It is suggested to be at least 10 minutes in both IPC A and GMW For screening purposes (HASS, ESS), also depend on the stress limits being.

Author: Grobar Kar
Country: Iceland
Language: English (Spanish)
Genre: Health and Food
Published (Last): 27 October 2004
Pages: 488
PDF File Size: 4.41 Mb
ePub File Size: 6.20 Mb
ISBN: 507-2-68069-507-5
Downloads: 14030
Price: Free* [*Free Regsitration Required]
Uploader: Nern

Durability Growth through HALT/HASS and Accelerated Testing

The P-Chart will be preferred as it can accommodate slight variations in sample size. Plastic cases should be removed to allow electronics to reach higher temperatures.

The average Xbar and sample standard deviation s of the three values for each parameter should be calculated. The monitoring process should facilitate root cause analysis.

We think you have liked this presentation. The use of the accelerometer on the product is critical in HALT to assess the level of energy that is being conveyed into the product via fixturing method from the table input. The equipment required to perform HALT testing must be capable of producing thermal and vibration energy stresses as defined below, and to create these stresses in a combined environment, i.

Example of Vibration Calibration: The thermal transitions are performed at the maximum attainable rate of change. Specific thermal and vibration data measurements supported by tables, graphs, photographs as appropriate? This larger sample 3 size is in contrast to the single sample usually evaluated in HALT for product improvement. Compared to vibration from Electrodynamic ED shaker, RS shakers offer two main features that are beneficial for defect precipitation in electronics systems.

  KOERNER GEOSYNTHETICS PDF

The use of thermocouple wire is required. Record this value as OLvibration-tstat. For Design Improvement Purpose.

These meetings shall occur prior to and subsequent to the product HALT. This should include the results of a failure analysis lab, if used, with pictures of damage at the flawed site.

Typical Defects Precipitated by this Stress. Corrective Action CA – A change implemented in a design or process to eliminate a product weakness or flaw.

A sample of 40 to 50 is suggested for each plotted point. Note that the functional test should be performed throughout the step, however it must minimally be performed at the conclusion of the ten-minute dwell.

My presentations Profile Feedback Log out. These “trends” are defined in most quality control textbooks. Functional testing is performed at the conclusion of the ten-minute dwell period. The empirical experience will provide a reasonable degree of safety margin for the screen. Apart from assessment of vibration 8827 of electronic parts and systems, and for stress screening.

The test samples should be uniquely identified by a serial number or other means of identification. This acronym has also become the service mark of the Qualmark Corporation to denote their version of this type of test chamber.

Random Vibration (RS)

The worst-case direction will be used to calibrate the input vibration level. The attachment of the thermocouples and accelerometers should be performed ggmw described in the section on HALT.

This report identifies the results and provides data that summarizes the results. HASS may continue during normal production for very critical products. This thermocouple should not be placed on or near a heat-generating component, or inside a totally closed portion of a product. Simultaneous multi-axial vibration generates synergistic effects of all modes being excited and a more realistic vibration stress loading condition, which better approximates real world vibrations being experienced by products The stress profile shown in Figure 1 at the bottom resembles the test descriptions in IPC A, IEST-RP-PR Several decision milestones should be considered because the 20 times concept is somewhat arbitrarily chosen.

  CATRAX PLUS PDF

Random Vibration (RS) | Center for Advanced Life Cycle Engineering

The measurement of vibration will define the offset value to be used in setting the table input vibration level. The reason constant monitoring is essential is the potential for unveiling a product problem is constantly changing during the screen.

This will help direct if and when a second fixture will be required. Identify maximum and minimum temperature for critical materials under test The RCA process begins during the HALT test, as functional limitations or failures are encountered efforts are made to understand the failure mode.

Complete functional gmmw immediately follows the dwell period and may also be performed throughout the step. The product thermocouple is attached to a location GMW that provides an accurate approximate average of the temperature of the sample.

This is beneficial to allow the sample to be stressed at higher levels of stress in order to find additional failure modes.