KAHRAMAA QATAR REGULATIONS PDF

L O D = Qatar General Electricity & Water Corporation . KAHRAMAA hereby certifies that the WORK under the said CONTRACT has been. State of Qatar Qatar General Electricity and Water Corporation “KAHRAMAA” Regulations for the Installation of Electrical Wiring, Electrical EquipmentAnd Air. Any deviation to this regulation to be noticed to the Qatar General Electricity & Water Corporation “KAHRAMAA” by the contractor or consultant. These.

Author: Kigajind Mezilabar
Country: Cape Verde
Language: English (Spanish)
Genre: Relationship
Published (Last): 11 October 2017
Pages: 255
PDF File Size: 7.74 Mb
ePub File Size: 13.87 Mb
ISBN: 561-6-70126-848-7
Downloads: 56123
Price: Free* [*Free Regsitration Required]
Uploader: Aragar

Means cylindrical closed vessel capable of containing water under pressure greater than atmospheric pressure. Copy of project contract.

Regulations of Internal Water Installations and Connection Works

In designing plumbing systems, utilize new techniques and options that can lead to maximum water efficiency. Treated water entering the distribution system. Means a person who is of a communal service. There are some forms in the appendix: Main Water Meter Cabinet: Plate indicating the customer number fixed as requirements on the corresponding premises, see figure Drawing No.

Reference to ” Customer ” in these byelaws shall fill the required applicant as defined before. Fire System In Multistory Buildings: Every layer rfgulations wooden box shall be clamped properly to avoid abrasion during transit and damage to coating or as specified elsewhere in the specification. Swimming Pool Circulating System. Determine the lifting pump total head to exceed the tower’s height, otherwise a break tanks at suitable floor level is regylations, other pump set required to convey water to the roof storage tanks.

For those multi stories buildings, the water tanks must be closer to the tie in point. Means the International Organization for Standardization.

Means the pipes and fittings in premises after the ground storage tank and any pipes and fittings between the storage tanks and the termination of the water network service connection, which shall normally be at the meter. Preparing periodic reports about the number of applications and number of permits issued etc to update the relevant Government authorities and agencies.

  CRYSTAL REPORTS CALIBRI PDF

Nominal pipe size in mm [ nominal rehulations diameter x nominal wall thickness ]. Any Application has to be contained the following requirements: The pump set must have sufficient head as mentioned in the approved drawings; the pump upstream supply pipe must be minimum mm.

Means the pipes, tanks, pumps, fittings and apparatus in any premises installed specifically for fire fighting application. During the winter and spring periods, sever electrical storms with sheet and forked lightning can occur.

Proposed location of Fuel System incorporated in the layout 4. The valve shall close clockwise. If there is combine tanks supplying fire, irrigation, or both, allusiveness both domestic and fire demand must be determine by consultant at the relevant form see appendix form BPW.

Estimate fees for building permits. Service cabinet must be installing on the boundary wall to reegulations nearest point reguoations KAHRAMAA water networks either in front of the premises or at the back, but must be closer to the main ground water tank.

Building Permit Complex Centre, Tel. Buildings where Qatari’s living for the purpose of settling in the plant areas, where building permit are issued.

Means those individual meters down stream of the main meter or sub main through which conveyed water to flats or villa in building or complex.

Mean pipe braches from main water pipe to inside compound Complex through which water conveyed to the inside the complex, in case of complex composed of villa and buildings. It is very important to detect the pump’s total head and the height of the premises and relevant loses.

The pump sets must have minimum one extra pump as stand by pump. Means any pipe Other Than an Overflow or a Flushing Pipe conveying water from storage cistern, hot water apparatus supplied by a feed cistern or under pressure from that cistern.

Both documents are provided below. The guidelines that must be considered while designing the plumbing system for new and addition to existing buildings by all consultants, customers and developers, are as follow: Determine the proposal pump total head, selection of appropriate set of pumps for the required total head sufficient for conveying the domestic water to the roof akhramaa.

  AZBOX NEWGEN MINI MANUAL PDF

Fire system inside residential complex will be approved by CDD, in case separate firewater tank, water meter upstream of the tank is required. The rainfall is concentrated in the winter and spring period December To March with an average of 50 – 80 mm per annum.

A copy Of Qatar Civil Defense requirements is split into two documents, the first one containing the guidelines and the second one is an Annex. Means any device other than a draw off tap, for stopping the flow of water in a pipe. Sample 3 Test 3 for CEE The capacity of the main tanks Reservoir will be 0.

Coil Length 25 1. Applicants Property Owners intending to install plumbing systems must ensure that the systems comply with the requirements of this regulations.

Regulations of Internal Water Installations and Connection Works

Receiving and studying applications for building permits. Means the water system that includes the distributing pipe and all associated apparatus within premises up to the point where water been drawn for customer use.

These standards have a set of specification for the materials usage. For dual flush tanks: In Residential Complex were water drawn to feed or supply water cistern. The maximum flow rate from aerators shall not exceed 2. Copy of commercial registration with activity approved by SSD. Means set of pumps boosting water from the main cistern to the villa or flat utilities.